SMX12-1-PXV/2

Free programmable and configurable compact safety controller

  • Integrated drive monitoring for up to 2 axes
  • 6 Encoder interfaces (with one safePXV encoder interface)
  • 14 safe digital inputs 
  • Up to 5 safe switch-off channels
  • Safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Optional: safe/non-safe fieldbus interface

Variants

Characteristic of the module

Characteristic of the module

  • Extendable up to:
    • max. 42 safe digital inputs
    • max.12 safe digitale outputs
    • max. 20 safe digital I/O‘s
    • max. 9 safe relay outputs
    • max. 10 auxiliary outputs
    • max. 2 safe axis
  • Freely programmable for the safe processing of Emergency stop buttons, two-hand operation, Light grids, mode selectors, etc.
  • Complete speed and position-related safety functions for drive monitoring for one or two axes
  • Safe position monitoring with only one sensor in combination with the optical reading head PXV100AS-F200-R4-V19-BBH
  • Speed monitoring
  • Standstill monitoring
  • Direction monitoring
  • Safe incremental dimension
  • Emergency Stop monitoring
  • Position monitoring
  • Position range monitoring
  • Trend range monitoring
  • Target position monitoring
  • Logic diagram oriented programming via SafePLC²
  • Pulse outputs for cross-shorting detection of digital input signals
  • External contact mon itoring of connected switchgear (EMU)
  • Switchable safe semi-conductor outputs pn-, pp- switching for safety-relevant functions
  • Monitored relay outputs for safety relevant functions
  • Comprehensive diagnostics functions integrated
  • Parameter management for expansion modules in base device
  • Coded status display via front-side 7 segment display and status LEDs
  • Multifunction button (quit, start, reset)  operated from the front side
  • Configurable via SafePLC² über USB serial adapter or ethernet based field bus
  • Extended functionality: SafePXV-encoder interface
  • Integrated Memory Card
  • Extended functionality:
    • allows the connection of 2 rotary encoder per axis (SSI-Absolut, Sin/Cos,TTL, HTL proximity switch)
    • 2. encoder interface also support HTL (200 kHz), Sin/Cos High-Resolution and Resolver
  • Optional: integrated Communication interface :
    • Standard and safe field bus protocols for communication with a higher level controller (PROFIBUS, PROFINET, DeviceNet, CANopen, EtherNET/IP, EtherCAT, Modbus TCP, PROFIsafe, FSoE)
    • Safe cross communication (SMMC) for data exchange between multiple base devices
    • Field bus protocols with the same hardware can be switched with SafePLC²
    • Safe remote I/O communication for data exchange with distributed I/O systems
  • The mechanical structure of SMX12-1-PXV/2 (/x*) is depended on the respective form of the base module

* Optional: integrated communication interface (/DNM, /DBM)

Order information

Base modules

ItemDescriptionItem No.
SMX12-1-PXV/2Base modul, safe drive monitoring for up to 2 axes, with 1 safePXV encoder interfaceon request
SMX12-1-PXV/2/DBase module + decentralized communicationon request
SMX12-1-PXV/2/DNMBase module + decentralized communication + ethernet based fieldbus interface + Memory Card2611
SMX12-1-PXV/2/DNM-FSoEBase module + decentralized communication + ethernet based fieldbus interface + Memory Cardon request
SMX12-1-PXV/2/xNMBase module + ethernet based fieldbus interface + Memory Card2612
SMX12-1-PXV/2/xNM-FSoEBase module + ethernet based fieldbus interface + Memory Cardon request
SMX12-1-PXV/2/xxMBase module + Memory Cardon request
SMX12-1-PXV/2/DBMBase module + decentralized communication + CAN based fieldbus interface + Memory Cardon request
SMX12-1-PXV/2/xBMBase module + CAN based fieldbus interface + Memory Cardon request

Accessories

Item

DescriptionItem No.

SMX91

SMX programming cable

1010
SMX91/2

SMX interface converter; Set with USB connection cable typ USB-B, shielded, for connection SMX 91/2 - PC, serial interface cable with 2x RJ10 connectors to connect SMX 91/2 to SMX assembly

(new model)

4304

SXxxxx-x

Plug-in screw terminals in a set, coded, for cabling SMX12-PXV/2, with labels

on request

SXxxxx-x

Plug-in spring terminals in a set, coded, for SMX12-PXV/2 cabling, with labels

on request

SX0000-9

T-Bus connector, voltage-carrying (grey)1015

SXxxxx-x

Y-Cable for encoder splitting

on request

FSoE License

Fieldbus license for FSoE

2366

PROFIsafe License

Fieldbus license for PROFIsafe

2319

PXV100AS-F200-R4-V19-BBH

Optical read head for incident light positioning system

2581

Extensions

Item

DescriptionItem No.

SMX31/2

I/O expansion module

1705

SMX31R/2

I/O expansion module with relay option

2046

SMX31R-4/2

I/O expansion module with relay option

2047

Software

Item

DescriptionItem No.
SAFEPLC² 1STProgramming software, 1st license incl. hardlock1244
SAFEPLC² 2NDProgramming software, 2nd license incl. hardlock1646
SAFEPLC² 3RDProgramming software, 3rd license incl. hardlock1647

Downloads