SMX12-1-PXV/2
Free programmable and configurable compact safety controller
- Integrated drive monitoring for up to 2 axes
- 6 Encoder interfaces (with one safePXV encoder interface)
- 14 safe digital inputs
- Up to 5 safe switch-off channels
- Safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
- Optional: safe/non-safe fieldbus interface
Variants
Characteristic of the module
Characteristic of the module
- Extendable up to:
- max. 42 safe digital inputs
- max.12 safe digitale outputs
- max. 20 safe digital I/O‘s
- max. 9 safe relay outputs
- max. 10 auxiliary outputs
- max. 2 safe axis
- Freely programmable for the safe processing of Emergency stop buttons, two-hand operation, Light grids, mode selectors, etc.
- Complete speed and position-related safety functions for drive monitoring for one or two axes
- Safe position monitoring with only one sensor in combination with the optical reading head PXV100AS-F200-R4-V19-BBH
- Speed monitoring
- Standstill monitoring
- Direction monitoring
- Safe incremental dimension
- Emergency Stop monitoring
- Position monitoring
- Position range monitoring
- Trend range monitoring
- Target position monitoring
- Logic diagram oriented programming via SafePLC²
- Pulse outputs for cross-shorting detection of digital input signals
- External contact mon itoring of connected switchgear (EMU)
- Switchable safe semi-conductor outputs pn-, pp- switching for safety-relevant functions
- Monitored relay outputs for safety relevant functions
- Comprehensive diagnostics functions integrated
- Parameter management for expansion modules in base device
- Coded status display via front-side 7 segment display and status LEDs
- Multifunction button (quit, start, reset) operated from the front side
- Configurable via SafePLC² über USB serial adapter or ethernet based field bus
- Extended functionality: SafePXV-encoder interface
- Integrated Memory Card
- Extended functionality:
- allows the connection of 2 rotary encoder per axis (SSI-Absolut, Sin/Cos,TTL, HTL proximity switch)
- 2. encoder interface also support HTL (200 kHz), Sin/Cos High-Resolution and Resolver
- Optional: integrated Communication interface :
- Standard and safe field bus protocols for communication with a higher level controller (PROFIBUS, PROFINET, DeviceNet, CANopen, EtherNET/IP, EtherCAT, Modbus TCP, PROFIsafe, FSoE)
- Safe cross communication (SMMC) for data exchange between multiple base devices
- Field bus protocols with the same hardware can be switched with SafePLC²
- Safe remote I/O communication for data exchange with distributed I/O systems
- The mechanical structure of SMX12-1-PXV/2 (/x*) is depended on the respective form of the base module
* Optional: integrated communication interface (/DNM, /DBM)
Order information
Base modules
| Item | Description | Item No. |
| SMX12-1-PXV/2 | Base modul, safe drive monitoring for up to 2 axes, with 1 safePXV encoder interface | on request |
| SMX12-1-PXV/2/D | Base module + decentralized communication | on request |
| SMX12-1-PXV/2/DNM | Base module + decentralized communication + ethernet based fieldbus interface + Memory Card | 2611 |
| SMX12-1-PXV/2/DNM-FSoE | Base module + decentralized communication + ethernet based fieldbus interface + Memory Card | on request |
| SMX12-1-PXV/2/xNM | Base module + ethernet based fieldbus interface + Memory Card | 2612 |
| SMX12-1-PXV/2/xNM-FSoE | Base module + ethernet based fieldbus interface + Memory Card | on request |
| SMX12-1-PXV/2/xxM | Base module + Memory Card | on request |
| SMX12-1-PXV/2/DBM | Base module + decentralized communication + CAN based fieldbus interface + Memory Card | on request |
| SMX12-1-PXV/2/xBM | Base module + CAN based fieldbus interface + Memory Card | on request |
Accessories
Item | Description | Item No. |
SMX91 | SMX programming cable | 1010 |
| SMX91/2 | SMX interface converter; Set with USB connection cable typ USB-B, shielded, for connection SMX 91/2 - PC, serial interface cable with 2x RJ10 connectors to connect SMX 91/2 to SMX assembly (new model) | 4304 |
SXxxxx-x | Plug-in screw terminals in a set, coded, for cabling SMX12-PXV/2, with labels | on request |
SXxxxx-x | Plug-in spring terminals in a set, coded, for SMX12-PXV/2 cabling, with labels | on request |
SX0000-9 | T-Bus connector, voltage-carrying (grey) | 1015 |
SXxxxx-x | Y-Cable for encoder splitting | on request |
FSoE License | Fieldbus license for FSoE | 2366 |
PROFIsafe License | Fieldbus license for PROFIsafe | 2319 |
PXV100AS-F200-R4-V19-BBH | Optical read head for incident light positioning system | 2581 |
Extensions
Item | Description | Item No. |
SMX31/2 | I/O expansion module | 1705 |
SMX31R/2 | I/O expansion module with relay option | 2046 |
SMX31R-4/2 | I/O expansion module with relay option | 2047 |
Software
Item | Description | Item No. |
| SAFEPLC² 1ST | Programming software, 1st license incl. hardlock | 1244 |
| SAFEPLC² 2ND | Programming software, 2nd license incl. hardlock | 1646 |