SMX 12-2A/2
Free programmable and configurable compact safety controller
- Integrated drive monitoring for up to 2 axes with extended encoder functionality
- 8 encoder interfaces
- 14 safe digital inputs
- 2 safe analog inputs
- Up to 5 safe switch-off channels
- Compact safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
- Optional: safe/non-safe fieldbus interface
Variants
Characteristic of the module
Characteristic of the module
- Expandable up to:
- max. 42 safe digital inputs,
- max. 12 safe digital outputs,
- max. 20 safe digital I/Os,
- max. 9 safe relay outputs,
- max. 10 auxiliary outputs,
- max. 2 safe axes
- Freely programmable for the safe processing of emergency stop buttons, two-hand operation, light curtains, operating mode selector switches, etc.
- Complete speed and position-related safety functions for drive monitoring of one or two axes
- Speed monitoring
- Standstill monitoring
- Direction of rotation monitoring
- Safe increment
- Emergency stop monitoring
- Position monitoring
- Position/travel range monitoring
- Target position monitoring
- Function plan-oriented programming using SafePLC2
- Pulse outputs for cross-circuit detection of digital input signals
- External contact monitoring of connected switching devices (EMU)
- Switchable safe outputs pn-, pp-switching for safety-relevant functions
- Monitored relay outputs for safety-related functions
- Extensive diagnostic functions integrated
- Parameter management for expansion modules in the base module
- Coded status display via 7-segment display on the front and status LEDs
- Multifunction button (Quit, Start, Reset) can be operated from the front
- Configurable with SafePLC2 via USB serial adapter or Ethernet-based fieldbus
- Extended functionality:
- Allows the connection of up to 2 encoders per axis (SSI, TTL, HTL proximity sensor)
- Extended encoder interface also supports a high-resolution HTL (200 kHz), sin/cos high-resolution and resolver
- Optional: integrated communication interface:
- Standard and safe fieldbus protocols for communication with a higher-level controller (PROFIBUS, PROFINET, CANopen, EtherCAT, Modbus TCP, PROFIsafe, FSoE)
- Safe cross communication (SMMC) for data exchange between several base devices
- Fieldbus protocols with the same hardware can be switched using SafePLC2
- Safe remote IO communication for data exchange with distributed IO systems
- The mechanical design of the SMX12-2A/2 (/x*) depends on the respective version of the base module
* Optional: integrated communication interface (/DNM, /DBM)
Order information
Base modules
| Item | Description | Item No. |
| SMX12-2A/2 | Base module with analog option (voltage + current), drive monitoring for up to 2 axes with extended encoder functionality | 2032 |
| SMX12-2A-I/2 | Base module with analog option (current) | 2294 |
| SMX12-2A-U/2 | Base module with analog option (voltage) | 2295 |
| SMX12-2A/2/D | Base module with analog option (voltage + current) + decentralized communication | 2033 |
| SMX12-2A-I/2/D | Base module with analog option (current) + decentralized communication | 2296 |
| SMX12-2A-U/2/D | Base module with analog option (voltage) + decentralized communication | 2297 |
| SMX12-2A/2/DNM | Base module with analog option (voltage + current) + decentralized communication + Ethernet-based fieldbus interface + memory card | 1768 |
| SMX12-2A-I/2/DNM | Base module with analog option (current) + decentralized communication + Ethernet-based fieldbus interface + memory card | 2300 |
| SMX12-2A-U/2/DNM | Base module with analog option (voltage) + decentralized communication + Ethernet-based fieldbus interface + memory card | 2301 |
| SMX12-2A/2/DNM-FSoE | Base module with analog option (voltage + current) + decentralized communication + Ethernet-based fieldbus interface + memory card | 2035 |
| SMX12-2A/2/xNM | Base module with analog option (voltage + current) + Ethernet-based fieldbus interface + memory card | 1716 |
| SMX12-2A-I/2/xNM | Base module with analog option (current) + Ethernet-based fieldbus interface + memory card | 2302 |
| SMX12-2A-U/2/xNM | Base module with analog option (voltage) + Ethernet-based fieldbus interface + memory card | 2303 |
| SMX12-2A/2/xNM-FSoE | Base module with analog option (voltage + current) + Ethernet-based fieldbus interface + memory card | 2036 |
| SMX12-2A/2/xxM | Base module with analog option (voltage + current) + memory card | 2037 |
| SMX12-2A-I/2/xxM | Base module with analog option (current) + memory card | 2304 |
| SMX12-2A-U/2/xxM | Base module with analog option (voltage) + memory card | 2305 |
| SMX12-2A/2/DBM | Base module with analog option (voltage + current) + decentralized communication + CAN-based fieldbus interface + memory card | 1769 |
| SMX12-2A-I/2/DBM | Base module with analog option (current) + decentralized communication + CAN-based fieldbus interface + memory card | 2306 |
| SMX12-2A-U/2/DBM | Base module with analog option (voltage) + decentralized communication + CAN-based fieldbus interface + memory card | 2307 |
| SMX12-2A/2/xBM | Base module with analog option (voltage + current) + CAN-based fieldbus interface + memory card | 1770 |
| SMX12-2A-I/2/xBM | Base module with analog option (current) + CAN-based fieldbus interface + memory card | 2308 |
| SMX12-2A-U/2/xBM | Base module with analog option (voltage) + CAN-based fieldbus interface + memory card | 2309 |
Accessories
Item | Description | Item No. | |
SMX91 | SMX Programming adapter | 1010 | |
SX0120-63 | Terminal connector, screw terminals (set), encoded for cabling SMX12-2A/2 | 2156 | |
SXxxxx-x |
| on request | |
SX0000-9 | T-Bus connector volltage-carrying (grey) | 1015 | |
SXxxxx-x | Y-cable for encoder splitting | on request | |
FSoE license | Fieldbus license for FSoE | 2366 | |
PROFIsafe license | Fieldbus license for PROFIsafe | 2319 |
Extensions
item | description | item no. |
SMX31/2 | I/O expansion module - SMX compact | 1705 |
SMX31R/2 | I/O expansion module with relay option - SMX compact | 2046 |
SMX31R-4/2 | I/O expansion module with relay option - SMX compact | 2047 |
Software
item | description | item no. |
SafePLC² 1st | Programming software, 1te License incl. Hardlock | 1244 |
SafePLC² 2nd | Programming software, 2te License incl. Hardlock | 1646 |
SafePLC² 3rd | Programming software, 3te License incl. Hardlock | 1647 |