SMX 11/2

Free programmable and configurable compact safety controller

  • Integrated drive monitoring for 1 axis
  • 3 encoder interfaces
  • 14 safe digital inputs
  • Up to 4 safe digital outputs
  • Up to 5 safe switch-off channels
  • Small safety controller suitable up to PL e (EN ISO 13849-1) or SIL3 (IEC 61508)
  • Optional: safe/non-safe fieldbus interface

 


Note: SMX11/2 is identical 1:1 to the SMX11 HI.


 

Variants

Characteristic of the module

Characteristic of the module

  • Extendable up to: 
    • max. 42 safe digital inputs,
    • max. 12 safe digital outputs,
    • max. 20 safe digital I/O‘s,
    • max. 9 safe relay outputs,
    • max. 10 auxiliary outputs,
    • max. 1 safe axis
  • Free programmable for the safe processing of emergency stop buttons, two-hand controls, light curtains, mode selection switches, etc.
  • Comprehensive speed- and position-related safety functions for drive monitoring integrated into the firmware
  • Spatial functions for safe speed and zone monitoring are possible
  • Speed monitoring:
  • RPM-monitoring
  • Standstill monitoring
  • Sense of rotation monitoring
  • Safe incremental dimension
  • Emergency Stop monitoring
  • Position monitoring
  • Position range monitoring
  • Trend range monitoring
  • Target position monitoring
  • Freely programmable modular controller for up to 800 IL instructions
  • Logic diagram oriented programming via SafePLC²
  • Pulse outputs for cross-shorting detection of digital input signals
  • External contact mon itoring of connected switchgear (EMU)
  • Switchable safe semi-conductor outputs pn-, pp- switching for safety-relevant functions
  • Monitored relay outputs for safety relevant functions
  • Comprehensive diagnostics functions integrated
  • Parameter management for expansion modules in base device
  • Coded status display via front-side 7 segment display and status LEDs
  • Multifunction button (quit, start, reset) can be operated from the front side
  • Configurable via SafePLC² über USB serial adapter or ethernet based field bus
  • Optional: integrated Communication interface : 
    • Standard and safe field bus protocols for communication with a higher level controller
      (PROFIBUS, PROFINET, CANopen, EtherCAT, Modbus TCP, PROFIsafe, FSoE)
    • Safe cross communication (SMMC) for data exchange between multiple base devices
    • Field bus protocols with the same hardware can be switched with SafePLC²
    • Safe remote I/O communication for data exchange with distributed I/O systems
  • The mechanical structure of SMX11/2 (/x*) is depended on the respective forms of the base module

* Optional: integrated communication interface (/DNM, /DBM)

Order information

Base modules

ItemDescriptionItem no.

SMX11/2

Basic module with integrated movement monitoring of one axis

2001

SMX11/2/D

Basic module + decentralised communication2002

SMX11/2/DNM

Basic module + decentralised communication + Ethernet-based field bus interface + Memory Card1749

SMX11/2/DNM-FSoE

Basic module + decentralised communication + Ethernet-based field bus interface + Memory Card2004

SMX11/2/xNM

Basic module + Ethernet-based field bus interface + Memory Card1750

SMX11/2/xNM-FSoE

Basic module + Ethernet-based field bus interface + Memory Card2005

SMX11/2/xxM

Basic module + Memory Card2006

SMX11/2/DBM

Basic module + decentralised communication + CAN-based field bus interface + Memory Card1751

SMX11/2/xBM

Basic module + CAN-based field bus interface + Memory Card1752

Accessories

Item

DescriptionItem no

SMX91

SMX Programming adapter

1010
SMX91/2

SMX interface converter; Set with USB connection cable typ USB-B, shielded, for connection SMX 91/2 - PC, serial interface cable with 2x RJ10 connectors to connect SMX 91/2 to SMX assembly

(new model)

4304

SXxxxx-x

Terminal connector, screw terminals (set), encoded for cabling SMX11/2on request

SXxxxx-x

Terminal connector, springterminals (set), encoded for cabling SMX11/2

on request

SX0000-9

T-Bus connector volltage-carrying (grey)1015

SXxxxx-x

Y-cable for encoder splittingon request

FSoE License

Fieldbus license for FSoE

2366

PROFIsafe License

Fieldbus license for PROFIsafe

2319

Extensions

item

descriptionitem no.

SMX31/2

I/O expansion module - SMX compact

1705

SMX31R/2

I/O expansion module with relay option - SMX compact 

2046

SMX31R-4/2

I/O expansion module with relay option - SMX compact

2047

Software

Item

DescriptionItem no.
SafePLC² 1st Programming software, 1st License incl. Hardlock 1244
SafePLC² 2ndProgramming software, 2nd License incl. Hardlock1646
SafePLC² 3rdProgramming software, 3rd License incl. Hardlock1647

Downloads